Gasinfrastruktur - Rörledningar (pipelines) för maximalt arbetstryck över 16 bar - Funktionskrav
Status:
Gällande
Köp denna standard
StandardSvensk standard
·
SS-EN 1594:2013
Gasinfrastruktur - Rörledningar (pipelines) för maximalt arbetstryck över 16 bar - Funktionskrav
Prenumerera på standarder med tjänst SIS Abonnemang. Genom att prenumerera får du effektiv åtkomst till gällande standarder och säkerställer att ditt företag alltid har tillgång till senaste utgåvan.
Läs mer om SIS Abonnemang
This European Standard is applicable to pipelines with a maximum operating pressure (MOP) over 16 bar for the carriage of processed, non-toxic and non-corrosive natural gas according to EN ISO 13686 in onland gas infrastructure. This European Standard is also applicable to pipelines with a maximum operating pressure (MOP) over 16 bar for the carriage of non-conventional gases such as injected biomethane, complying with EN ISO 13686 and for which a detailed technical evaluation of the functional requirements is performed ensuring there are no other constituents or properties of the gases that can affect the integrity of the pipeline. Onland gas infrastructure is where: - pipeline elements are made of unalloyed or low-alloyed carbon steel; - pipeline elements are joined by welds, flanges or mechanical couplings; - the pipeline is not located within commercial or industrial premises as an integral part of the industrial process on these premises except for any pipelines and facilities supplying such premises; - the design temperature of the system is between -40 °C and 120 °C inclusive. This European Standard applies to onshore pipeline systems from the point where the pipeline first crosses what is normally accepted as battery limit between on and offshore, e.g.: - first isolation valve; - the base of steep sea shelf; - above the high water/low water mark onto mainland; - an island. This European Standard also applies to a pipeline system with a starting point onshore, also when parts of the pipeline system on the mainland subsequently cross fjords, lakes etc. This European Standard does not apply to existing pipelines, in use prior to the publication of this European Standard, nor to modifications to existing pipelines. Gas infrastructures covered by this European Standard begin after the gas producer's metering station. The functional demarcation of the pipeline system within a plant area will be determined from case to case. Generally speaking, this will be dire...
Gasinfrastruktur - Rörledningar (pipelines) för maximalt arbetstryck över 16 bar - Funktionskrav
Prenumerera på standarder med tjänst SIS Abonnemang. Genom att prenumerera får du effektiv åtkomst till gällande standarder och säkerställer att ditt företag alltid har tillgång till senaste utgåvan.
Läs mer om SIS Abonnemang