Standard Svensk standard · SS-EN 14662-5:2005

Utomhusluft - Standardmetod för mätning av bensenkoncentrationer - Del 5: Diffusionsprovtagning med efterföljande lösningsmedelsdesorption och gaskromatografi

Status: Gällande

Köp denna standard

Standard Svensk standard · SS-EN 14662-5:2005

Utomhusluft - Standardmetod för mätning av bensenkoncentrationer - Del 5: Diffusionsprovtagning med efterföljande lösningsmedelsdesorption och gaskromatografi
Prenumerera på standarden - Läs mer Dölj
Pris: 1 152 SEK
standard ikon pdf

PDF

Pris: 1 152 SEK
standard ikon

Papper

Pris: 1 843,20 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ
Provläs denna standard
Omfattning
This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period.
This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air, by diffusive sampling, solvent desorption and capillary gas chromatography.
This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 µg/m3 to 50 µg/m3 in an air sample typically collected over a period of several days or several weeks. A number of devices are recommended for the sampling of benzene, each device having a different range of applicability, particularly with regard to the optimum period of exposure.
The upper limit of the useful range is set by the sorptive capacity of the activated charcoal and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the
sampling devices or in the carbon disulphide.
Alternative sorbents to activated charcoal may be used provided that the equivalence in performance
characteristics of the procedure is demonstrated.
Alternative desorption solvents to carbon disulphide may be used provided that the equivalence in
performance characteristics of the procedure is demonstrated.

Ämnesområden

Omgivningsluft (13.040.20)


Köp denna standard

Standard Svensk standard · SS-EN 14662-5:2005

Utomhusluft - Standardmetod för mätning av bensenkoncentrationer - Del 5: Diffusionsprovtagning med efterföljande lösningsmedelsdesorption och gaskromatografi
Prenumerera på standarden - Läs mer Dölj
Pris: 1 152 SEK
standard ikon pdf

PDF

Pris: 1 152 SEK
standard ikon

Papper

Pris: 1 843,20 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Utomhusluft, SIS/TK 423/AG 04

Internationell titel: Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography

Artikelnummer: STD-39951

Utgåva: 1

Fastställd: 2005-06-14

Antal sidor: 31