Scope
This document covers hinged or pivoted doorsets and door assemblies with wood-based door leaves and/or timber framed glazed door leaves and openable timber framed windows. Throughout this document, the term “doorset” will be used to cover doorsets, door assemblies and openable windows. It prescribes the rules for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
This document covers only doorsets with wood-based or metal frames. The door leaves are comprised of wood-based perimeter framing and wood-based structural facings.
Subject to the completion of the appropriate test or tests, the extended application can cover all or some of the following examples:
- integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classifications;
- glazing within the doorset, e.g. side and over panels, vision panels and framed glazed doorsets;
- air transfer grilles (e.g. ventilation grilles/louvres);
- side, transom or over panels;
- items of building hardware;
- decorative and protective finishes;
- intumescent strips and non-intumescent seals (e.g. smoke, draught or acoustic seals);
- alternative supporting construction(s).
This document covers only the effect on the fire resistance classifications E, EW, EI1 and EI2.
This document does not cover horizontal doorsets.

Subjects

Fire-resistance of building materials and elements (13.220.50) Doors and windows (91.060.50)


Buy this standard

Standard Swedish standard · SS-EN 15269-3:2022

Extended application of test results for fire resistance and/or smoke control for doorsets, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows
Subscribe on standards - Read more Dölj
Price: 2 027 SEK
standard ikon pdf

PDF

Price: 2 027 SEK
standard ikon

Paper

Price: 3 243,20 SEK
standard ikon pdf + standard ikon

PDF + paper

Show more Show less

Product information

Language: English

Written by: Std Samhäll

International title:

Article no: STD-80039472

Edition: 2

Approved: 11/21/2022

No of pages: 204

Replaces: SS-EN 15269-3:2012